Power pack EN 8 / LC / SLC
The EN 8 LC power pack represents the state of the art. The monitoring which is integrated in the secondary area indicates that the partial discharge inception voltage (= start of effect of ionization units / ill.1) is too low by making the monitoring LED blink. The compact printed circuit board technology ensures reliability and ease of maintenance. The device has four gas-tight high-voltage connections and has been manufactured in accordance with protection type IP 54, protection class I as per VDE.
The EN 8 LC power pack supplies voltage to ionizers. The mains voltage is transformed into a 7–8 kVAC by a high-voltage transformer.
Power pack EN 8
Identical to power pack EN 8 LC, but without integrated watchdog function.
Special features and advantages
- simple and fast checking of ionization unit
- reliable information concerning manufacturing process (process and quality control)
- continuous monitoring of the ionization unit without additional testing and measuring equipment
Possible EN 8 LC configurations
Power pack EN 8 LC | + EI VS ionizing bar |
+ EI VSA ionizing bar | |
+ EI RN ionizing bar | |
+ EI RE ring electrode |
Branches
Plastic processing industry: Film extruders, film processing, in the manufacture of plastic tubes, sections, shells and rods and in plastic extruders
Packing industry: Packing machines, filling machines and bag manufacture
Graphics industry: Folding machines, print processing
Electrical industry: Printed circuit board manufacture
- Glass industry: Plate glass manufacture
Technical data
Types | EN 8 | 115V 230V | Order-No.: 01.7756.000 Order-No.: 01.7757.000 |
EN 8 LC | 115V 230 V | Order-No.: 01.7756.100 Order-No.: 01.7757.100 | |
Protection type | IP 54 | ||
Protection class | I | ||
Supply voltage | 115 VAC / 230 VAC (50 – 60 Hz) | ||
Power consumption | approx. 50 VA | ||
Output-voltage | approx. 7 – 8 kVAC | ||
Output short-circuit current | (lk) ≤ 5 mA | ||
HV-terminals | 4 | ||
Connectable length | max. 18 m (ionizing unit incl. HV-cable) | ||
Operating temperature | +5 °C to +45 °C | ||
Storage/transport temperature | -15 °C to +60 °C | ||
Weight | approx. 5 kg | ||
Mains cable | 2.6 m; fixed to the device |
Subject to technical changes!